Généralités :
- Clean up code dealing with door and window operation and construction type.
- Clean up code dealing with getting Solids from element geometry.
- Finalize support for FM Handover view. The new functionality for this is included in the lists below.
- Replace native function call to create some columns as extrusions with .NET code.
- Renamed the shared parameters for many entity properties to have "Ifc" at the front.
- Sort parameter names on export to minimize changes in IFC file from subsequent exports of the same file.
Nouvelles fonctionnalités :
- Add 11 new IFC common parameter sets, including: Pset_AirTerminalTypeCommon, Pset_DistrubutionFlowElementCommon, Pset_FlowTerminalAirTerminal, Pset_SpaceOccupancyRequirements, Pset_PlateCommon, Pset_ReinforcingBar*Common
- Add support for IfcLengthMeaure parameter export.
- Add support IfcCircleHollowProfileDef; use for extrusions if appropriate.
- Add support for Provisions for Voids.
- Allow specification and export of a user-defined classification system, instead of just Uniformat.
- Allow exporting elements as IfcDiscreteAccessory/IfcDiscreteAccessoryType.
- Allow "IfcExportAs" to take both the entity name and the type name in the format "IfcEntityName.TypeName".
- Export base quantities for 5 elements: IfcBuildingStorey, IfcCovering, IfcDoor, IfcSpace, IfcWindow. Some of these were already supported and were just moved from native to .NET.
- Export FabricArea and FabricSheet as IfcReinforcingMesh and IfcGroup, respectively.
- Note: that the default export settings have these set as "Not Exported" - these have to be updated manually to "IfcReinforcingMesh" and "IfcGroup".
- Export ceilings as extrusions or BReps if possible, instead of just surface models.
- Export surface styles by default for Coordination View 2.0.
- Include Ceiling as a room bounding element on export if it is part of only one room.
- Stabilise GUIDs for Pset_Building/BuildingStorey/SiteCommon, internal Revit property sets, and slabs in roof containers (only for the case of an IfcRoof containing a single IfcSlab, however).
Corrections de bugs :
- Changed incorrect "PSet" to correct "Pset" for various parameter set names.
- Don't create openings for doors and windows when the host is exported as parts
- Don't export RepresentationMap for IfcTypeProduct with 0 items.
- Don't ignore an internal Revit parameter on export if it has the same name as a parameter in another group.
- Export materials for IfcReinforcementBar; make body representation "AdvancedSweptSolid".
- Fix export of grids so that only one IfcShapeRepresentation is created.
- Fix export of some extruded columns that were split into separate components by other elements.
- Fix issue where classification reference was not exported in non-English versions of Revit.
- Make "NosingLength" parameter of PSet_StairFlightCommon IfcLengthMeasure.
- Make GetExportTypeFromClassName not reject some unrecognized IFC class names.
- Move the local placement of many entities with extrusions and mapped representations for geometry to be closer to the geometry.
- Properly export Pset_ZoneCommon for IfcZones.
- Properly label some mislabelled IfcOpeningElements as "Opening" or "Recess".
- Properly scale door panel properties, window frame properties, and base quantities on export.
- Remove incorrect PsetLightFixtureCommon.ArticleNumber property.
|